FlexibleLoad

A FlexibleLoad models demand the optimizer may set anywhere within a range: a cold store that can run harder when power is cheap, a process that can slow down when it's expensive, or a site in a demand response programme.

Each scenario gives the range at every step, and the optimizer decides where in it the load runs, weighing what the consumption is worth against what the power costs.

Basic usage

Let's add a flexible process to the site: each MWh it consumes is worth 60 $/MWh to the site.

from odys import FlexibleLoad

process = FlexibleLoad(name="process", value_of_consumption=60.0)

Fields

Field Type Required Default Description
name str Yes - Unique name of the load
value_of_consumption float Yes - Value of each MWh consumed, at least 0 (currency/MWh)
min_load float \| None No None Least the load can consume while running, at least 0 (MW)
max_load float \| None No None Most the load can consume while running, above 0 (MW)
ramp_up float \| None No None Fastest the consumption can rise, at least 0 (MW per hour)
ramp_down float \| None No None Fastest the consumption can fall, at least 0 (MW per hour)
commitment Commitment \| None No None How the load switches on and off; None keeps it always on

min_load can't be above max_load.

Value of consumption

value_of_consumption is what each MWh the load consumes is worth to you. It's what the optimizer weighs against the cost of the power the load would draw:

  • When it's above what one more MWh costs, from your generators or the market, the optimizer runs the load higher.
  • When it's below, the optimizer runs the load lower, and uses or sells that power elsewhere.

The process above is worth 60 $/MWh. When the CCGT at 50 $/MWh is the most expensive supply running, the process runs as high as it can. With value_of_consumption=0.0, consuming is worth nothing, so the optimizer keeps the load at its lower bound whenever power costs anything at all.

The cost of the power never appears on the load itself: it shows up in the generators and markets that supply it. See the objective contribution.

Profiles

Every flexible load needs a FlexibleLoadProfile in every scenario. It gives the range the load can run in at each step: lower_bound is the least it consumes, and upper_bound the most, both in MW. Say the process can run anywhere from 20 to 50 MW:

from odys import FlexibleLoadProfile, Scenario

scenario = Scenario(
    profiles=(FlexibleLoadProfile(load=process, lower_bound=[20, 20, 20, 20], upper_bound=[50, 50, 50, 50]),),
)

The range can change from step to step, and from one scenario to the next: a process that has to keep a furnace warm overnight, or an order that may or may not come in.

Each step stands on its own: energy not used now isn't used later, and without ramp limits the load can jump across its whole range from one step to the next. See FL-1.

Building a FlexibleLoadProfile raises an OdysValidationError unless, at every step, the lower bound is at least 0 and at most the upper bound, and both bounds have the same number of values.

Physical limits

min_load and max_load are the load's own limits, whatever the scenario: a hard minimum to keep it running, or what its connection allows. Every bound of every scenario has to fit inside them:

from odys import OdysValidationError

compressor = FlexibleLoad(name="compressor", max_load=40.0, value_of_consumption=60.0)

try:
    FlexibleLoadProfile(load=compressor, lower_bound=[20, 20], upper_bound=[40, 45])
except OdysValidationError as error:
    print(error)
Flexible load 'compressor' has an upper bound (45.0) above max_load (40.0) at time index 1.

Results

Let's add the process to the CCGT, the wind farm and the factory, and read its results through result.flexible_loads:

from datetime import timedelta

from odys import AssetPortfolio, AvailableCapacityProfile, EnergySystem, FixedLoad, Generator, LoadProfile

ccgt = Generator(name="ccgt", nominal_power=100.0, variable_cost=50.0)
wind = Generator(name="wind", nominal_power=80.0, variable_cost=0.0)
factory = FixedLoad(name="factory")

energy_system = EnergySystem(
    portfolio=AssetPortfolio([ccgt, wind, factory, process]),
    scenarios=Scenario(
        profiles=(
            LoadProfile(load=factory, values=[60, 90, 40, 70]),
            FlexibleLoadProfile(load=process, lower_bound=[20, 20, 20, 20], upper_bound=[50, 50, 50, 50]),
            AvailableCapacityProfile(generator=wind, values=[40, 10, 60, 30]),
        ),
    ),
    timestep=timedelta(hours=1),
    number_of_steps=4,
)

result = energy_system.optimize()
print(result.flexible_loads.to_dataframe())
                    consumption  status  startup  shutdown
time flexible_load
0    process               50.0     1.0      0.0       0.0
1    process               20.0     1.0      0.0       0.0
2    process               50.0     1.0      0.0       0.0
3    process               50.0     1.0      0.0       0.0

result.flexible_loads has four series, each a pandas.Series indexed by load and time, and by scenario when there's more than one:

  • consumption: what the load consumes, in MW;
  • status: 1 while the load runs, 0 while it's off. A load without a commitment is always on;
  • startup and shutdown: 1 at the step the load starts or stops.

Every MWh of the process is worth 60 $/MWh and the most expensive supply, the CCGT, costs 50 $/MWh, so the optimizer runs the process at its upper bound whenever it can. At step 1 the factory needs 90 MW and only 110 MW of supply is available, so the process drops to its lower bound instead.

The Industrial Demand Response example plans a cement kiln with ramps and on/off through a full day of day-ahead prices.

Ramp limits

A big process can't change its draw in an instant: a kiln heats up and cools down slowly. ramp_up and ramp_down say how fast its consumption can change, in MW per hour:

kiln = FlexibleLoad(name="kiln", value_of_consumption=40.0, ramp_up=20.0)

With hourly steps, the kiln's consumption rises by at most 20 MW from one step to the next; with 15-minute steps, by 5 MW. Without ramp_down, it can fall as fast as it likes. At the first step, the limit counts from where the load was just before the run, its initial state. See FL-3 and FL-4.

Switching on and off

Some processes can stop altogether, but can't run below a minimum stable load: a kiln runs between 30 and 70 MW, or not at all. Give such a load a Commitment, the same one a generator takes:

from datetime import timedelta

from odys import Commitment

kiln = FlexibleLoad(
    name="kiln",
    value_of_consumption=40.0,
    ramp_up=20.0,
    commitment=Commitment(min_up_time=timedelta(hours=2), startup_cost=200.0),
)

Now at every step the kiln is either off, at 0 MW, or running within its FlexibleLoadProfile range, so the lower bound becomes its minimum stable load. Once started, it runs for at least 2 hours, and each start costs 200. A Commitment can also hold a min_down_time and a shutdown_cost. Without a commitment, a load is always on and never consumes less than its lower bound.

Ramps only limit the change between two steps the load runs: a start can land anywhere in the range, and a stop drops straight to 0. See FL-2.

Initial state

A ramp limit, a minimum up or down time and a start-up or shut-down cost all depend on where the load was before the run. So as soon as a load has one, odys asks for a FlexibleLoadInitialState: its load, its power just before the first step, and, for a load with a commitment, its time_in_state, how long it has been running, or off when power is 0. time_in_state is needed when the matching minimum time is set, and it has to be a whole number of steps. power is 0, for a load that can switch off, or within min_load and max_load.

Say the kiln has been running at 30 MW for an hour, and only the wind farm is cheaper than what the kiln's output is worth, with a lull in the middle of the day:

from odys import FlexibleLoadInitialState

ccgt = Generator(name="ccgt", nominal_power=100.0, variable_cost=60.0)

energy_system = EnergySystem(
    portfolio=AssetPortfolio([ccgt, wind, kiln]),
    scenarios=Scenario(
        profiles=(
            FlexibleLoadProfile(load=kiln, lower_bound=[30] * 6, upper_bound=[70] * 6),
            AvailableCapacityProfile(generator=wind, values=[70, 70, 10, 10, 80, 80]),
        ),
    ),
    timestep=timedelta(hours=1),
    number_of_steps=6,
    initial_conditions=(FlexibleLoadInitialState(load=kiln, power=30.0, time_in_state=timedelta(hours=1)),),
)

result = energy_system.optimize()
print(result.flexible_loads.to_dataframe())
                    consumption  status  startup  shutdown
time flexible_load
0    kiln                  50.0     1.0      0.0       0.0
1    kiln                  70.0     1.0      0.0       0.0
2    kiln                   0.0     0.0      0.0       1.0
3    kiln                   0.0     0.0      0.0       0.0
4    kiln                  70.0     1.0      1.0       0.0
5    kiln                  70.0     1.0      0.0       0.0

The kiln climbs from 30 MW as fast as its ramp allows, 20 MW an hour, to run on the free wind. During the lull, staying on at its 30 MW floor would mean burning CCGT power worth less than it costs, and climbing back at 20 MW an hour once the wind returns. Stopping is better: at step 4 it restarts straight at 70 MW, for one start-up of 200.

How it's modelled

A flexible load has one decision per step: how much it consumes, and, with a commitment, whether it runs. FL-1 keeps it between the lower and the upper bound while it runs, FL-3 and FL-4 limit its ramps, and all of the consumption is valued at value_of_consumption in the objective, less the start-up and shut-down costs. The rule, why it's written that way, and its limitations are on the Flexible loads formulation page.

Next steps

A flexible load changes how much you consume, not when. To move energy from one step to another, store it: see Battery.